ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE Performing a node-based submodeling analysisFor an overview of submodeling that includes some details common to both node-based and surface-based submodeling, see About submodeling. Your submodel analysis is driven, either partly or completely, from the results obtained from a global model analysis. The results from the global model are interpolated onto the nodes on the appropriate parts of the boundary of the submodel (see Figure 1). Thus, the response at the boundary of the local region is defined by the solution for the global model. The driven nodes and any loads applied to the local region determine the solution in the submodel. Figure 1. The global model.
Different types of node-based submodelingThree different techniques are available for nodal-based submodeling. Solid-to-solid submodelingThe linear or nonlinear response of a global solid model can be used to drive the submodel response of a solid submodel. The driven variables can be displacements or temperatures. Shell-to-solid submodelingThe linear or nonlinear response of a global shell model can be used to drive the submodel response of a solid submodel. The driven variables are displacements, which are determined from global model displacements and rotations. Acoustic submodelingThe linear or nonlinear response of a global, structural model can be used to drive the acoustic response of a fluid region of any size if the forces exerted on the structure by the fluid are small. This is often the case for metal structures in air, building interiors, or for sound propagation from a liquid to air. In the case of a liquid and a gas, no special procedures need be followed; the pressure degrees of freedom couple straightforwardly. In the case of a structure driving a fluid, you must ensure that the degrees of freedom to be driven in the submodel exist among the global model results. Several alternatives exist. A thin layer of fluid elements, with the same properties as the submodel fluid, can be added to the global model; this element set and its nodes can then be used to drive the submodel in the usual manner. Alternatively, you can create acoustic interface elements on the surface of the submodel and drive the corresponding nodes with the structural nodes (see Fully and sequentially coupled acoustic-structural analysis of a muffler). In problems where the fluid exerts large pressures on the structure, the mechanical response of the structure may be of interest. Acoustic-to-structure submodeling can be used in such problems. The submodel in these problems is a part of the structural component of the global model. The acoustic pressure obtained from solving a coupled acoustic-structural global analysis is used to drive the submodel on the surface it shares with the fluid medium. Other boundaries of the submodel may be driven using the displacements of the structural component of the global model via solid-to-solid submodeling. The acoustic-to-structure submodel analysis solves an uncoupled structural force-displacement problem. The acoustic pressure from the global model is interpolated to the submodel driven nodes. The tributary area and the outward normal associated with the driven node are used to convert the interpolated acoustic pressure to a concentrated load acting at that location (see Miscellaneous submodeling tests). Saving the results from the global modelThe results from the global analysis must be saved at all nodes required for the interpolation of the driven variables to the boundary of the submodel (see Figure 1). The results (.fil) file or the output database (.odb) file can be used for this purpose. Saving the results to the results fileIn each step of the global model whose solution will be used to drive the submodel, write the nodal results for all driven variables to the results file (see Output to the Data and Results Files). These results must be written in the global coordinate system of the model. The submodel can refer only to a global model results file that is from a binary compatible platform. When the global model is run in Abaqus/Explicit and results file output is requested, the results are written to the selected results (.sel) file; this file needs to be converted into a results (.fil) file using the convert option (see Abaqus/Standard and Abaqus/Explicit execution). Input File Usage NODE FILE (In Abaqus/Standard GLOBAL=NO should not be used on the NODE FILE option.) Abaqus/CAE Usage You cannot write output to the results file in Abaqus/CAE. Saving the results to the output databaseIn each step of the global model whose solution will be used to drive the submodel, write the nodal results for all driven variables to the output database in ODB or SIM format (see Output to the Output Database). Unlike the results file, nodal output to the output database is always written in the global directions. The output database can be transferred to any platform since it is binary neutral. Abaqus/CAE Usage Step module: Saving results with higher precisionBy default, the nodal output to the output database is written using single precision, which may not be sufficient for certain classes of problems; for example, submodels undergoing large rigid body motions (consider also surface-based submodeling in these cases—see Surface-based submodeling). For such analyses request the nodal output to the fullest possible precision (see Abaqus/Standard and Abaqus/Explicit execution). Input File Usage abaqus job=global_model_input_file output_precision=full Abaqus/CAE Usage Job module: Create Job: Precision: Nodal output precision: Full Saving results from a global model with a physical time scaleIf the global analysis in Abaqus/Standard involves a physical time scale and the results file is to be used in the submodel analysis, request that the results file output be written at the beginning of the step (the zero increment) for all steps in the global analysis (see About Output). Abaqus will then have the complete solution history (including the solution state at the beginning of a step) from which a submodel may be driven. If the zero increment results are not requested, incorrect results will be obtained if the step time in the submodel is less than the step time of the first increment on the results file. Instead of interpolating between the results at the start of the step and the results of the first increment on the results file, Abaqus will simply use the results of the first increment as long as the submodel step time is less than the step time of the first increment on the results file. The zero increment request is not required in Abaqus/Explicit, because the results are always written to the results file at the beginning of each step. Similarly, the results will always be correctly interpolated when using the output database to transfer the results from the global model to the submodel, because the zero increment is always written to the output database. Input File Usage FILE FORMAT, ZERO INCREMENT Abaqus/CAE Usage You cannot write output to the results file in Abaqus/CAE. Referring to the global model results from the submodel analysisYou must define the source of the global solution results. Provide the name of the global results file or output database file (in ODB or SIM format); the file extension is optional. If the file extension is omitted, Abaqus will use in order, the results file, the ODB output database file, or the SIM database file. Input File Usage abaqus job=submodel_input_file globalmodel=global_results_file or global_output_database or sim_database_file Abaqus/CAE Usage Any module: Submodel: Read data from job: global_results_file or global_output_database: Reading data from a SIM database file is not supported in Abaqus/CAE. Specifying the driven nodes in the submodelSpecifying the driven nodes does not activate the driven variables: they must be activated by specifying the appropriate submodel boundary conditions. All nodes of the submodel where variables will be driven in any step (see Figure 2) must be specified as driven nodes since the list of nodes cannot be extended subsequent to its initial definition (even at restart). However, variables at the nodes given do not have to be driven in all steps: the choice of which variables are driven in a particular step is made as part of a submodel boundary condition definition, as discussed later. Figure 2. The magnified submodel.
Input File Usage SUBMODEL list of nodes or node set labels or, for acoustic-to-structure submodeling, the name of an element-based structural surface The SUBMODEL option must be included in the model definition portion of the input file for the submodel analysis. Multiple SUBMODEL options are allowed; however, in this case you must ensure that the driven nodes specified on the data line of one option are separate and distinct from the nodes specified on the data lines of all the other options. Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region Specifying the driven nodes in shell-to-solid submodelingIn shell-to-solid submodeling, the submodel is made up of solid elements and replaces a region where conventional shell elements are used in the global model. In this case Abaqus expects that all the driven nodes on the submodel belong to solid elements and are driven from a global model region that is entirely made up of shell elements. The boundary where the submodel is driven is a set of surfaces in the submodel but is a set of lines in the shell reference surface in the global model, as shown in Figure 3. The dashed line on the shell model is replaced by the shaded surfaces of the solid element submodel. Figure 3. Shell-to-solid submodeling.
Whenever shell-to-solid submodeling is used, you must define the maximum shell thickness in the global model, given in the units used for the models. If a shell offset is defined in the global model, the shell thickness must be set equal to twice the maximum distance from the top or bottom shell surface to the shell reference surface. Input File Usage SUBMODEL, SHELL TO SOLID, SHELL THICKNESS=thickness If more than one SUBMODEL option is used, the SHELL TO SOLID parameter must be included on every option. Abaqus/CAE Usage Any module: Submodel: Shell global model drives a solid submodel Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Shell thickness: thickness: Specifying the driven nodes in acoustic-to-structure submodelingThe global analysis for acoustic-to-structure submodeling problems is performed as a coupled acoustic-structural analysis. The acoustic nodal pressures from the global analysis must be written to the results file for the acoustic mesh in contact with the structural surface of interest. In the submodel analysis acoustic pressures from the global analysis drive the user-specified structural surface of interest. The driven nodes for the submodel are the nodes lying on the specified surface. Only element-based surfaces are allowed in acoustic-to-structure submodeling. Input File Usage SUBMODEL, ACOUSTIC TO STRUCTURE, ABSOLUTE EXTERIOR TOLERANCE=value Abaqus/CAE Usage Acoustic-to-structure submodeling is not supported in Abaqus/CAE. Specifying driven nodes for shells with acoustic pressures on both sidesIn certain problems the acoustic pressure may act on both sides of a shell structure. Figure 4 shows a section of a global model consisting of a shell structure that is sandwiched between two acoustic media. Figure 4. A cross-section of the acoustic-to-structure global model with
acoustic regions on both sides of the shell.
Separate element sets consisting of acoustic elements on the positive and negative sides of the shell are defined, respectively. The nodal pressures for nodes attached to elements in these sets are written to the selected results file. Figure 5 shows the submodel that consists only of the refined shell structure. Figure 5. The acoustic-to-structure submodel with acoustic pressure on both
sides of the shell.
Two separate surfaces are defined on the SPOS and SNEG sides, respectively. To apply the acoustic pressure from the global analysis on each side of the shell correctly, you must specify the surface name along with the corresponding acoustic element set. Input File Usage SUBMODEL, ACOUSTIC TO STRUCTURE, GLOBAL ELSET=Acoustic_SPOS Shell_SPOS SUBMODEL, ACOUSTIC TO STRUCTURE, GLOBAL ELSET=Acoustic_SNEG Shell_SNEG Abaqus/CAE Usage Acoustic-to-structure submodeling is not supported in Abaqus/CAE. Defining geometric tolerancesA geometric tolerance is used to define how far a boundary node in the submodel can lie outside the exterior surface of the global model, as that surface is interpolated in the global, undeformed finite element model. By default, nodes in the submodel must lie within a distance calculated by multiplying the average element size in the global model by 0.05. You can change the tolerance, which is useful in cases where submodel driven nodes lie to a greater extent outside the global model exterior surface. Tolerances larger than this default value, however, may result in significantly greater computation times and lower accuracy in the driven solution for driven nodes significantly outside the global model exterior surface. You can define the geometric tolerance as a fraction of the size of the average element in the global model or as an absolute distance in the length units chosen for the model. If both tolerances are defined, Abaqus uses the tighter tolerance. Input File Usage Use the following option to define the geometric tolerance as an absolute distance: SUBMODEL, ABSOLUTE EXTERIOR TOLERANCE=tolerance Use the following option to define the geometric tolerance as a fraction of the size of the average element in the global model: SUBMODEL, EXTERIOR TOLERANCE=tolerance Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Exterior tolerance: absolute: or relative: tolerance The exterior tolerance in solid-to-solid submodelingThe exterior tolerance for a solid-to-solid submodel analysis is indicated by the shaded region in Figure 6. If the distance between the driven nodes and the free surface of the global model falls within the specified tolerance, the solution variables from the global model are extrapolated to the submodel. Figure 6. The exterior tolerance in solid-to-solid submodeling.
The exterior tolerance in shell-to-shell submodelingIn a shell-to-shell submodel analysis Abaqus checks whether the driven nodes of the submodel lie sufficiently close to the reference surface of the shell elements in the global model. To simplify calculations, the closest point in the global model is calculated as the intersection of a line drawn through the node on the submodel with the reference surface of the shell in the global model. The direction of the line is normal to a flat surface approximation to each shell element. The normal to the flat surface is the average of the normals at the nodes of the shell element. The distance checked against the specified exterior tolerance is shown in Figure 7. Figure 7. Flat surface approximation in shell-to-shell submodeling.
The exterior tolerance in shell-to-solid submodelingFor shell-to-solid submodeling Abaqus uses two kinds of tolerances to determine the relationship between the submodel and the global model. First, the closest point on the shell reference surface of the global model is determined. This point, the “image node,” is shown in Figure 8. The user-specified exterior tolerance is used to check if the image node lies within the domain of the global model. Then the distance, , between the driven node and its image is checked; if the distance is less than half the value of the specified shell thickness plus the exterior tolerance, it is accepted. This check is only approximate if the global model has varying shell thickness or if the shell reference surface is offset from the midsurface. Figure 8. The exterior tolerance in shell-to-solid submodeling.
Permitting driven nodes to be excluded from submodelingIn some cases (such as when your submodel geometry is more detailed than the global model in regions near a free surface) you may specify driven nodes that Abaqus will find, even when accounting for the search tolerance, to be outside the region of the global model elements. By default, these cases result in an error message. In solid-to-solid submodeling you can, however, specify that Abaqus ignore driven nodes that cannot be found. Use this option with caution and always evaluate the list of nodes that are labeled as not found. Most cases where Abaqus finds driven nodes to lie outside the global model reflect a modeling error and use of the intersection only option may lead to incorrect results in these cases. Input File Usage Use the following option to specify that Abaqus ignore driven nodes that cannot be found in the global model elements: SUBMODEL, INTERSECTION ONLY list of nodes or node set labels The driven nodes ignored through the use of the INTERSECTION ONLY parameter are then ignored in all subsequent submodel boundary condition references. Defining the driven variables in the submodelThe actual driven variables are defined in any step as a submodel boundary condition. The boundary conditions are “driven variables” obtained from the results or output database file of the global analysis. The degrees of freedom on the driven nodes of the submodel must exist at the forcing nodes of the global model. In a problem involving an acoustic fluid submodel driven by a structural global model, for example, acoustic interface elements should be created on the submodel's driven boundary with the structure. For solid-to-solid and shell-to-shell submodeling specify the individual degrees of freedom to be driven. In most cases all components of the solution variables (displacements, rotations, temperatures, etc.) at these nodes are driven by the global solution, although you may choose to drive only some components at any of the driven nodes. For shell-to-solid submodeling the driven degrees of freedom are chosen automatically based on a user-specified zone around the shell reference surface, as explained later. Abaqus/Explicit does not admit jumps in displacement and rotation boundary conditions (see Prescribed displacement); any jumps in the driven displacements and rotations will be ignored. It is not recommended to have all the variables at all the nodes in the submodel driven by the global solution. For acoustic-to-structure submodeling, the loads due to acoustic pressure acting at the driven nodes of the submodel are activated by specifying pressure (degree of freedom 8) along with the driven node set. Only one submodel boundary condition can be specified in each step of the analysis. Input File Usage BOUNDARY, SUBMODEL Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Degrees of freedom: degrees of freedom Specifying the step number from the global analysisYou specify the step of the global model history that is to be used for the driven variables in the current submodel analysis step. When the global solution is obtained from the results file, the zero increment is included if it was requested in the global analysis (see About Output). In a general analysis step or a direct-solution steady-state dynamic analysis step, Abaqus calculates the amplitudes for the driven variables as functions of time or frequency from the results of the global model. Input File Usage BOUNDARY, SUBMODEL, STEP=step Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Global step number: step Scaling the global time period to the submodel time periodThe global analysis and submodel analysis can have different time steps. You can scale the time variable of the driven nodes from the global analysis to the step time of the submodel analysis. This technique is useful when the analyses are static or quasi-static in nature; the use of this technique in dynamic analyses with significant inertial effects is not recommended. If the same step time is used in both the global model and the submodel, the time scale has no effect. The time scale cannot be specified in frequency domain analyses or in linear perturbation steps. Abaqus will determine the values that the driven variables will follow throughout the step in the submodel analysis by using the points in time at which the global solution results or output database file was written. When the time variable of the driven nodes of the global analysis is scaled and if the step time is different from the submodel step time, the points in time of the driven variables are scaled to the submodel step time. Input File Usage BOUNDARY, SUBMODEL, STEP=step, TIMESCALE Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Scale time period of global step to time period of submodel step Scaling the magnitude of driven variablesFor displacement-based submodeling the magnitude values of driven variables are obtained by multiplying the displacement history as obtained from the global analysis by a scaling parameter. You can scale the driven variables by setting the scaling parameter in the definition of the submodel boundary conditions. This technique is useful in scaling the submodel boundary conditions in a multiple-step analysis without rerunning the global model. It can be used in Abaqus/Standard and Abaqus/Explicit for the same-to-same and shell-to-solid cases except for acoustic-to-structure submodeling. Input File Usage BOUNDARY, SUBMODEL, STEP=step, SCALE=scalarValue Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Scale: scale Modifying the set of driven variablesYou can modify the submodel boundary condition to add new variables to the list of driven variables, you can remove variables from the driven variable set, and you can reintroduce them later (see Boundary conditions in Abaqus/Standard and Abaqus/Explicit). New nodes cannot be added to the total set of driven nodes defined for the submodel; this set of driven nodes is a fixed part of the model definition. Input File Usage Use one of the following options: BOUNDARY, SUBMODEL, OP=MOD BOUNDARY, SUBMODEL, OP=NEW Abaqus/CAE Usage Load module: boundary condition editor: Degrees of freedom Automatically selecting the driven variables in shell-to-solid submodelingFor shell-to-solid submodeling the driven degrees of freedom at the driven nodes are chosen automatically, depending on the distance between the driven node and the global model shell reference surface. All displacement components are driven at nodes that lie on the reference surface or within a “center zone,” as shown in Figure 9. The size of the center zone is specified as part of the submodel boundary condition definition, as described below. For nodes that lie further away from the reference surface, only the displacement components parallel to the shell reference surface are driven. At least one layer of nodes in the submodel must be within the center zone; if no nodes are found this close to the reference surface, Abaqus issues an error message. Figure 9. Center zone choice in shell-to-solid submodeling.
Specifying the size of the center zone in shell-to-solid submodelingThe center zone method of prescribing driven variables usually provides a reasonable transfer of the plane stress assumption in the shell model. The width of this zone around the reference surface where all displacement components are driven may be different for various driven nodes or node sets. If you do not provide values for the center zone size, a default value of 10% of the maximum of the specified shell thicknesses is assumed. For complicated geometries it can be advantageous to assign a different center zone size to different nodes or node sets. You can view the driven nodes lying inside and outside the center zone in Abaqus/CAE by displaying the model boundary conditions ( ) in the Visualization module. Input File Usage BOUNDARY, SUBMODEL, STEP=step nodes, center zone size Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Center zone size: center zone size Transferring transverse shear stresses in shell-to-solid submodelingUsually it is enough for the layer of nodes closest to the shell reference surface to lie inside the center zone. If a very fine solid mesh is used in the thickness direction and substantial transverse shear stresses are transferred, it may be necessary to make the center zone size large enough that multiple layers of nodes lie inside the zone. However, if the transverse shear stresses at the submodel boundary are high and the submodel is highly refined in the thickness direction, high local stresses may develop since the shear force at the submodel boundary is transferred only at the driven nodes within the center zone. High transverse shear stresses occur only in regions where bending moments vary rapidly; it is better not to locate the submodel boundary in such regions. It is best to locate the submodel boundary in areas of low transverse shear stress in the global model. Special considerationsThere are several special considerations that are worth noting. Specifying the shell thickness in shell-to-shell submodelingFor shell-to-shell submodeling the shell thickness generally is not changed between the models. You can specify different shell thicknesses if, for example, a local thickness change is being investigated; however, Abaqus does not check the validity of these differences. Limitations in shell-to-solid submodelingThe following limitations and special cases apply to the shell-to-solid capability:
Alternative to shell-to-solid submodelingAn alternative to shell-to-solid submodeling is the surface-based shell-to-solid coupling capability discussed in Shell-to-solid coupling. ProceduresNeither the coupled thermal-electrical procedure nor any of the mode-based dynamics procedures can be used on the submodel level. In addition, submodeling cannot be used in conjunction with symmetric model generation or symmetric results transfer. Adaptive meshes should not be used in the global model. However, they can be used in the submodel analysis; Abaqus will always treat the driven nodes in the submodel as Lagrangian nodes. Both general (possibly nonlinear) and linear perturbation steps can be used in submodeling (see General and perturbation procedures for a discussion of general and linear perturbation steps). Submodeling in dynamic proceduresThe submodeling capability can be used in the dynamic procedures using explicit integration (in Abaqus/Explicit) and in the dynamic procedures using direct integration (in Abaqus/Standard). The following combinations of procedures between the global model and the submodel can be considered: explicit dynamic, implicit dynamic, dynamic coupled thermal-stress, and coupled thermal-stress. In dynamic problems in which inertial forces are significant, the global model and the submodel need to be run for the same step time intervals. In Abaqus/Explicit a quasi-static analysis is performed as a dynamic procedure. For this case and for the static analyses performed in Abaqus/Standard, the time step of the global model and submodel can be different. The time variable of the driven nodes from the global analysis must be scaled to the step time of the submodel analysis to match the time variable of the amplitude functions generated at the driven nodes to the step time used in the submodel. For significantly dynamic problems in Abaqus/Explicit, a sufficiently large number of intervals need to be written to the results or output database file for the global model. Preferably the displacement results for the nodes that are used to drive the submodel should be saved for each increment. This caution is necessary in particular for problems with elastic material properties to avoid possible aliasing (under sampling), which can cause solution distortion in the submodel. These requirements do not apply to quasi-static problems. Interpreting acceleration resultsWhen you drive a submodel boundary with global model displacement results, the displacements are interpreted as a smoothed piecewise linear function in time, similar to how you would apply a displacement boundary condition using a tabular amplitude definition (see Using an amplitude definition with boundary conditions). This smoothed function typically results in displacements and velocities at the driven nodes that agree reasonably with the global model. Acceleration results at the driven boundary, however, are generally not in good agreement with the global model as they reflect the shape of the displacement history smoothing rather than the global model acceleration results (information that is not available from a piecewise linear global-model displacement history). The submodel acceleration results away from the submodel driven nodes are less affected by this smoothing and are typically in good agreement with the global model response. Obtaining a solution at a particular point in time using linear perturbation analysisIn Abaqus/Standard it is possible to study the submodel's linearized response corresponding to a particular point in time in the global solution by using a static, linear perturbation procedure in the submodel analysis. You can select the increment in the global analysis step that is to be used as the basis for calculating the values for the driven variables. If you do not select an increment in a static linear perturbation step, the last increment of the selected step in the global analysis is used as the basis for calculating the values for the driven variables. You cannot select an increment in a general submodel step. Input File Usage BOUNDARY, SUBMODEL, STEP=step, INC=increment Abaqus/CAE Usage Load module: Create Boundary Condition: choose Other for the Category and Submodel for the Types for Selected Step: select region: Global step number: step, Global increment: increment Submodeling in the frequency domainThe submodeling capability can be used in the frequency domain by using the direct-solution steady-state dynamics procedure. Mode-based steady-state dynamics cannot be used at the submodel level. The only restriction on the specification of the frequency range in the submodel is that the minimum and maximum frequency should lie within the range of calculated frequencies in the global model. Abaqus will interpolate the solution variables from the global model in the frequency domain, as well as spatially, before applying them to the submodel. The results will be most accurate if the frequencies at which the response in the submodel is requested match the frequencies at which the response was calculated in the global model. This is particularly true in the vicinity of the eigenfrequencies of the global model. In the global model you must write both the amplitude and the phase of the nodal displacements to the results file so that Abaqus can apply the real and imaginary parts of the solution at the driven nodes in the submodel. If you are using the output database to drive the submodel, you need to request only nodal displacement output since displacement output to the output database includes both real and imaginary parts. Mixing general and linear perturbation stepsIt is possible to mix general steps and linear perturbation steps in both the global and the submodel analyses. Abaqus allows general analysis steps to be treated as linear perturbation steps during submodeling, and vice versa. Example: Submodeling with general and linear perturbation stepsFor an example of submodeling that uses both general and linear perturbation steps, consider the following situation. The global analysis consists of a static preload—done as a general, nonlinear, analysis step—followed by extraction of the eigenmodes of the preloaded structure, then a step of 5 seconds of modal dynamic response analysis: STEP ** Apply preload STATIC 0.1, 1.0 … ** Write out results for nodes needed to ** interpolate to the submodel's boundary NODE FILE, NSET=DETAIL U END STEP STEP ** Calculate modes and frequencies FREQUENCY … ** The NODE FILE option is repeated because ** this is the first linear perturbation step NODE FILE, NSET=DETAIL U END STEP STEP ** Dynamic response of preloaded system MODAL DYNAMIC 0.01, 5.0 … END STEP We wish to study the local, possibly nonlinear, response of a part of this model that is so small that we do not need to model dynamic effects locally and can, thus, perform two steps of static analysis: ** Define submodel boundary (driven nodes) SUBMODEL PERIM STEP ** Preload STATIC 0.1, 1.0 BOUNDARY, SUBMODEL, STEP=1 … END STEP STEP ** Local static response to global dynamic step STATIC 0.01, 5.0 BOUNDARY, SUBMODEL, STEP=3 … END STEP It is perfectly acceptable that the submodel analysis requests general, possibly nonlinear, analysis for both steps, while in the global analysis the dynamic step was a linear perturbation step (modal dynamics is always a linear perturbation analysis). It is your responsibility to judge that this use of the submodeling feature is reasonable. For example, suppose that the global analysis were continued with a fourth step of general, nonlinear static response: RESTART, READ, STEP=3 ** Read state at end of initial preload ** (could equally well use RESTART, READ, STEP=1) STEP ** Add more preload STATIC 0.2, 1.0 … END STEP This fourth general analysis step starts with the state at the end of general analysis Step 1 because the frequency extraction and the modal dynamic steps are both linear perturbation steps. However, if we restart the submodel analysis in the same way, the solution may not be comparable with the global model solution: RESTART, READ, STEP=2 ** Read state at end of step 2 STEP ** Add more preload STATIC 0.2, 1.0 BOUNDARY, SUBMODEL, STEP=4 … END STEP The second step in the submodel is a general analysis step, to which the response may be nonlinear, thus changing the state of the model. A valid alternative would be to apply the Step 4 response to the submodel immediately after the first step: RESTART, READ, STEP=1 ** Read state at end of preload step STEP ** Add more preload STATIC 0.2, 1.0 BOUNDARY, SUBMODEL, STEP=4 … END STEP Reinterpreting solution variables in the submodel analysisDuring general analysis steps Abaqus works in terms of total solution variables such as the displacements, . In linear perturbation steps Abaqus works in terms of the displacement perturbation, , about a base state, . When general analysis steps and linear perturbation steps are reinterpreted in the submodel analysis, the global analysis results are treated as defined in Table 1.
In this table
Mixing general and linear perturbation steps in shell-to-solid submodelingAdditional assumptions must be made for the shell-to-solid case when a general procedure on the global model drives a linear perturbation procedure on the submodel and vice versa. The assumptions depend on the geometric formulation used (linear or nonlinear) and on the procedure combination. For details and governing equations for these cases, see Submodeling analysis. Initial conditionsThe definition of initial conditions should be consistent between the global model and the submodel. Boundary conditionsBoundary conditions (other than submodel boundary conditions) prescribed on the degrees of freedom that are driven will replace those prescribed using submodel boundary conditions. When this replacement occurs, Abaqus reports the change in the data file. A node can be driven from the global model in some steps and have user-prescribed boundary conditions in other steps. In these cases all relevant boundary conditions must be respecified (see Boundary conditions in Abaqus/Standard and Abaqus/Explicit). Any other boundary conditions that are applied in the submodel region should be imposed in the submodel analysis in the usual way. It is your responsibility to apply such prescribed boundary conditions to the submodel correctly so that they correspond to the loading of the global model. Be careful with submodel boundary nodes that are also on planes of symmetry, where both forms of boundary conditions can be applied. It may be helpful in such cases to apply boundary conditions in a local coordinate system (see Transformed coordinate systems). The local coordinate system should be applied only to the boundary conditions that are intended to override the submodel boundary conditions, since the submodel boundary conditions are always output in the global coordinate directions by the global model. LoadsAny loads that are applied in the submodel region must be imposed in the submodel analysis in the usual way. It is your responsibility to apply such loads to the submodel correctly so that they correspond to the loading of the global model. See About loads for an overview of the loads available in Abaqus. Predefined fieldsThe following predefined fields can be specified in a submodeling analysis, as described in Predefined Fields:
Abaqus interpolates solution variables onto the submodel driven nodes. It can also interpolate temperatures as field variables (see Interpolating data between meshes for details). Other predefined fields will not be interpolated to the nodes of the submodel; they must be available from the input data for all nodes of the submodel where they are required. Abaqus/Standard provides multiple approaches for cases where a submodel thermal-stress analysis must be performed using temperature solutions from a global heat transfer analysis.
Material optionsAny of the material models described in Abaqus Materials Guide can be used in the global and submodel analyses. The material response defined for the submodel may be different from that defined for the global model. ElementsThe dimensionality of the submodel must be the same as that of the global model: both models must be either two-dimensional or three-dimensional. The following limitations apply:
OutputAny of the output normally available within a particular procedure is also available during a submodeling analysis (see Abaqus/Standard output variable identifiers and Abaqus/Explicit output variable identifiers). As described above, nodal output requests to the results file or output database file must be used in the global analysis to save the values of the driven variables at the submodel boundary. Input file templateGlobal analysis:HEADING … STEP Step 1 STATIC (or DYNAMIC, etc.) Data line to define step time and control incrementation … NODE FILE List of solution variables to be used to drive the submodel OUTPUT, FIELD NODE OUTPUT List of solution variables to be used to drive the submodel END STEP Submodel analysis:HEADING … SUBMODEL, EXTERIOR TOLERANCE=tolerance List of all nodes to be driven ** STEP STATIC (or any other allowable procedure) Data line to define step time (must be the same as the step time in the global analysis unless the TIMESCALE parameter is used on the BOUNDARY option) and control incrementation … BOUNDARY, SUBMODEL, STEP=1 Data lines listing nodes and degrees of freedom to be driven in this step … END STEP |