Required parameters
- ELSET
-
Set this parameter equal to the name of the element set containing the MASS elements for which the value is being given.
Optional parameters
- ALPHA
-
Set this parameter equal to the factor to create mass proportional damping for the MASS elements when used in direct-integration dynamics or explicit dynamics. This value is ignored in modal dynamics. The default is 0.0.
- COMPOSITE
-
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the fraction of critical damping to be used with the MASS elements when calculating composite damping factors for the modes when used in mode-based analyses that are not based on the SIM architecture. The default is 0.0.
For mode-based analyses that are based on the SIM architecture, the COMPOSITE MODAL DAMPING option should be used instead. This value is ignored in direct-integration dynamics.
- ORIENTATION
-
This parameter applies only when TYPE=ANISOTROPIC.
Set this parameter equal to the name of an ORIENTATION option (Orientations) that is being used to define the principal directions of the anisotropic mass tensor. If the ORIENTATION parameter is omitted, it is assumed that the principal directions coincide with the global axes.
In a large-displacement analysis, the local axes of the anisotropic mass rotate with the rotation, if active, of the node to which the MASS element is attached.
- TYPE
-
Set TYPE=ISOTROPIC (default) for an isotropic mass tensor.
Set TYPE=ANISOTROPIC for an anisotropic mass tensor with possibly three different principal values.
Data line to define the magnitude of an isotropic mass (not weight)
- First (and only) line
Mass magnitude.
Abaqus does not use any specific physical units, so the user's choice must be consistent.
Data line to define the three principal values of an anisotropic mass tensor (not weight)
- First (and only) line
The principal mass about the local 1-axis, .
The principal mass about the local 2-axis, .
The principal mass about the local 3-axis, .
Abaqus does not use any specific physical units, so the user's choice must be consistent.