Required parameters
- PROPERTY
-
Set this parameter equal to the name of the INCIDENT WAVE PROPERTY option defining the incident wave field.
Required, mutually exclusive parameters
- ACCELERATION AMPLITUDE
-
Set this parameter equal to the name of the amplitude curve defining the fluid particle acceleration time history at the standoff point (Amplitude Curves). This amplitude curve will be used to compute the fluid traction only: a solid surface requiring a pressure load cannot be specified on the data line of an INCIDENT WAVE option if the ACCELERATION AMPLITUDE parameter is used.
This parameter is valid only for planar incident waves using the INCIDENT WAVE PROPERTY, TYPE=PLANE option. Reflected loads, using the INCIDENT WAVE REFLECTION option, are not permitted in this case.
- PRESSURE AMPLITUDE
-
Set this parameter equal to the name of the amplitude curve defining the fluid pressure time history at the standoff point (Amplitude Curves). The corresponding fluid traction, if required, will be computed from the pressure amplitude reference.
Data lines to define an incident wave
- First line
Surface name.
Reference magnitude.