Required parameters
- DEPENDENCIES
-
Set this parameter equal to the number of field variables included in the definition of the point capacitance. If this parameter is omitted, it is assumed that the point capacitance is constant or depends only on temperature. See Material data definition for more information.
- ELSET
-
Set this parameter equal to the name of the element set containing the HEATCAP elements for which the value is being given.
Data lines to define the capacitance magnitude
- First line
Capacitance magnitude. Capacitance (), not specific heat, should be given.
Temperature.
First field variable.
Second field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the point capacitance as a function of temperature and other predefined field variables. Abaqus does not use any specific physical units, so the user's choice must be consistent.