ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEInteraction module
Required parameters
- NAME
-
Set this parameter equal to a label that will be used to refer to this film property. This label is referred to on the data lines of the FILM or CFILM options.
Optional parameters
- DEPENDENCIES
-
Set this parameter equal to the number of field variables included in the definition of the film coefficient. If this parameter is omitted, it is assumed that the film coefficient depends only on temperature. See Material data definition for more information.
Data lines to define the film coefficient as a function of temperature and field variables
- First line
Film coefficient, h. (Units of JT−1L−2−1.)
Temperature.
First field variable.
Second field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to create a film property table.