Display the body force load editor using one of the following methods:
If the Distribution field appears in the editor, click the arrow to the right of the field, and select the option of your choice from the list that appears:
-
Select Uniform to define a load that is uniform over the body.
-
Select User-defined to define the magnitude of the load in user subroutine DLOAD (for Abaqus/Standard) or VDLOAD (for Abaqus/Explicit). See the following sections for more information:
-
Select an analytical field to define a spatially varying load. Only analytical fields that are valid for this load type are displayed in the selection list. Alternatively, you can click Create to create a new analytical field. (See The Analytical Field toolset,” for more information.)
If you selected the Uniform or analytical field distribution option, perform the following steps:
- In the Component 1, Component 2, and (if you are working in three-dimensional space) Component 3 fields, enter the body force per unit volume in each direction (units FL−3):
-
If you are working in three-dimensional or two-dimensional space, the Component 1, Component 2, and Component 3 fields correspond to the 1-, 2-, and (if applicable) 3-directions.
-
If you are working in axisymmetric space, Component 1 corresponds to the radial direction and Component 2 corresponds to the axial direction.
- If desired, click the arrow to the right of the Amplitude field, and select the amplitude of your choice from the list that appears. Alternatively, you can click to create a new amplitude. (See The Amplitude toolset,” for more information.)
- Click OK to save your data and to exit the editor.
If you selected the User-defined distribution option, perform the following steps:
- If desired, in the Component 1, Component 2, and (if applicable) Component 3 fields enter the body force per unit volume in each direction (units FL−3).
Load magnitude data that you enter in the editor are passed into the user subroutine in an Abaqus/Standard analysis but are ignored in an Abaqus/Explicit analysis.
- Click OK to save your data and to exit the editor.
- Enter the Job module and display the job editor for the analysis job of interest. (For more information, see Creating, editing, and manipulating jobs.)
- In the job editor, click the General tab, and specify the file containing the user subroutine that defines the load magnitude. For more information, see Specifying general job settings.
Note:
You can specify only one user subroutine file in the job editor; if your analysis involves more than one user subroutine, you must combine the user subroutines into one file and then specify that file.
|