ProductsAbaqus/StandardAbaqus/CAE
TypeModel data
LevelPartPart instanceAssembly
Abaqus/CAELoad module
Required parameters
- NODE
 
- 
Set this parameter equal to either the pre-tension node number or the name of a node set containing the pre-tension node. If the name of a node set is chosen, the node set must contain exactly one node.
 
 

Required, mutually exclusive parameters
- ELEMENT
 
- 
Set this parameter equal to either the element number of the truss or beam element used to define the pre-tension section or the name of an element set containing the truss or beam element used to define the pre-tension section. If the name of an element set is chosen, the element set must contain exactly one element.
 
- SURFACE
 
- 
Set this parameter equal to the name of the surface definition (SURFACE) that defines the pre-tension section (when continuum elements are used).
 
 

Data line to define the normal to the section (optional)
- First (and only) data line
 
First component of the normal.
 
Second component of the normal.
 
Third component of the normal.
 
If the data line is omitted, Abaqus/Standard will compute an average normal to the pre-tension section for continuum elements. For truss or beam elements the default normal points from the first to the last node in the element connectivity.