*GASKET ELASTICITY

Specify elastic properties for the membrane and transverse shear behaviors of a gasket.

This option is used to define the elastic parameters for the membrane and transverse shear behaviors of a gasket.

Related Topics
In Other Guides
Defining the gasket behavior directly using a gasket behavior model

ProductsAbaqus/StandardAbaqus/CAE

TypeModel data

LevelModel

Abaqus/CAEProperty module

Optional parameters

COMPONENT

Set COMPONENT=MEMBRANE to define the membrane behavior of a gasket.

Set COMPONENT=TRANSVERSE SHEAR (default) to define the transverse shear behavior of a gasket.

DEPENDENCIES

Set this parameter equal to the number of field variable dependencies included in the definition of the elastic parameters, in addition to temperature. If this parameter is omitted, it is assumed that the elastic parameters depend only on temperature. See Material data definition for more information.

VARIABLE

This parameter is used only with COMPONENT=TRANSVERSE SHEAR to specify the unit system in which the transverse shear behavior will be defined.

Set VARIABLE=FORCE to define the transverse shear stiffness in terms of force per unit displacement or force per unit length per unit displacement, depending on the element type to which this behavior refers.

Set VARIABLE=STRESS (default) to define the transverse shear stiffness in terms of stress per unit displacement.

Data lines for COMPONENT=TRANSVERSE SHEAR

First line
  1. Shear stiffness. (This value cannot be negative.)

  2. Temperature, θ.

  3. First field variable.

  4. Etc., up to six field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
  1. Seventh field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the dependence of the shear stiffness on temperature and field variables.

Data lines for COMPONENT=MEMBRANE

First line
  1. Young's modulus, E.

  2. Poisson's ratio, ν.

  3. Temperature, θ.

  4. First field variable.

  5. Etc., up to five field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five)
  1. Sixth field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the dependence of Young's modulus and Poisson's ratio on temperature and field variables.