ProductsAbaqus/StandardAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAELoad module
Optional parameters
- AMPLITUDE
-
Set this parameter equal to the name of the AMPLITUDE curve that defines the magnitude of the seepage flow during the step. If this parameter is omitted for uniform seepage types, the reference magnitude is applied immediately at the beginning of the step or linearly over the step, depending on the value assigned to the AMPLITUDE parameter on the STEP option (see Defining an analysis). Amplitude references are ignored for flows defined in user subroutine DFLOW.
- OP
-
Set OP=MOD (default) for existing DSFLOWs to remain, with this option modifying existing flows or defining additional flows.
Set OP=NEW if all existing DSFLOWs applied to the model should be removed. New flows can be defined.
Data lines to define uniform seepage
- First line
Surface name.
Distributed uniform seepage type label S.
Reference seepage magnitude. (Units of LT−1.) The seepage magnitude is the pore fluid effective velocity crossing the surface at this point in an outward direction.
Repeat this data line as often as necessary to define uniform seepage for various surfaces.
Data lines to define nonuniform seepage
- First line
Surface name.
Nonuniform distributed seepage type label SNU.
Seepage magnitude (optional). If given, this value is passed into user subroutine DFLOW in the variable used to define the seepage magnitude.
Nonuniform seepage magnitudes are defined via user subroutine DFLOW.
Repeat this data line as often as necessary to define nonuniform seepage for surfaces.