- In case that the settings entered in sub items of PRE_PROCESSING
item in Task Manager are incorrect, this is first revealed
when SIMULIA Tosca Structure
is started using START_OPTIMIZATION | RUN item.
If this is the case, or if the optimization does not succeed because
of another reason, the subdirectory DB_ERROR is created in
the job directory and the log file DB_ERROR/TOSCA.OUT
is opened in a new window in Tosca ANSA® environment
(see the following figure). Please refer to SIMULIA Tosca Structure
for the explanations of error messages. In ANSA
Info window, the message "SIMULIA Tosca Structure
Run, exit with errors!" is written.
Tosca ANSA® environment:
TOSCA.OUT file opened in a window. |
- If Tosca Structure.smooth
that was started using SMOOTH | SMOOTH_INSTANCE | RUN_SMOOTH
item fails, the message "cannot open '.../TOSCA_POST/SMOOTH_INSTANCE.onf':
Invalid argument" is written in ANSA Info window.
The error messages produced by SIMULIA Tosca Structure.control
(the component that starts Tosca Structure.smooth)
are written to the console where Tosca ANSA® environment
has been started; the error messages of Tosca Structure.smooth
itself are written to the console as well as saved in TOSCA_POST/TOSCA.OUT
file.
- When starting Tosca Structure.smooth
from Tosca ANSA® environment,
please make sure that TASK parameter of SMOOTH
RUN PARAMETERS window (opened by Edit command
applied on RUN_SMOOTH item) is assigned to the correct
value: TASK = ISO for topology optimization or TASK
= SURFACE for shape and bead optimization.
- When selecting groups in Tosca ANSA® environment,
make sure that the objects you select (nodes or elements) match the type
of the group. If the caption of the field where the group name is to
be selected says ND_GROUP (as in DESIGN_AREA
command for shape or bead optimization), set the selection mode to node
selection by highlighting the line in Database corresponding
to nodes; if it says EL_GROUP (as in DESIGN_AREA
command for topology optimization), the elements should be selected and
thus the line Elements of Database should be highlighted.
To highlight a line in Database, simply click it once;
in case of selecting elements, make sure that the check box in the line
is checked, otherwise the elements are hidden. If a group of inappropriate
type is selected, an empty group will appear in SIMULIA Tosca Structure
parameter file, and SIMULIA Tosca Structure
run will fail.
- Once SIMULIA Tosca Structure
started from within Tosca ANSA® environment
finishes successfully, be careful not to modify any parameters of SIMULIA Tosca Structure
task unless you wish to repeat the optimization. When a new optimization
starts, in case that the job name (the name of the item created by New
| Output command applied to PRE-PROCESSING item; default value is Output)
remains unchanged, the job directory is overwritten and all results from
the previous optimization run are lost. A new optimization is started
automatically when Update command is applied to any item situated below
START_OPTIMIZATION in Task Manager
(such as RUN_SMOOTH or SOLID_MESH) in case that the
item RUN under START_OPTIMIZATION is unchecked.
In case that this item is unchecked but the optimization results are
present, it is still possible to run further actions without repeating
the optimization; it suffices to apply Disable command to START_OPTIMIZATION
item (or to delete it completely).
- When starting the validation run using SMOOTH | VALIDATE | VALIDATION_RUN
item, make sure that the paths to the solver executables are correctly
written in the configuration file. See for details. Note that you may start the validation
run manually outside of Tosca ANSA® environment
since the validation run does not affect any further actions in Tosca ANSA® environment.
- Although it is possible to delete certain elements or merge different
models in Tosca ANSA® environment,
the optimization with SIMULIA Tosca Structure
only takes into account the geometry from the input file mentioned under
MODEL_LINK item. However, you may modify the result
of Tosca Structure.smooth
prior to RECONSTRUCT and SOLID_MESH
(or in between these actions) in any way, and the changes will be reflected
on the model for the validation run.
- The options of Tosca ANSA® environment
are edited in the dialog opened by Windows | Options... menu
command (see the following figure). The buttons "Save" and "Save
as" in Settings panel allow to save the configuration
of Tosca ANSA® environment,
including the paths to SIMULIA Tosca Structure
and the solvers. Saving the settings in a temporary file is a quick way
to check the current configuration.
Tosca ANSA® environment:
Options dialog. |
|