DRESP
ID_NAME = dresp_eig2
DEF_TYPE = SYSTEM
TYPE = DYN_FREQ
LC_SET = Modal,All,2
END_
OBJ_FUNC
ID_NAME = max_ dresp_eig2
DRESP = dresp_eig2
TARGET = MAX
END_
OPTIMIZE
ID_NAME = opt
DV = my_design_nodes
STRATEGY = BEAD_SENSITIVITY
OBJ_FUNC = max_ dresp_eig2
END_
OPT_PARAM
ID_NAME = my_parameters
OPTIMIZE = opt
MODETRACKING = ON
MODENUMBERS = 10
END_
The second mode is chosen to be maximized. The important difference is
that mode tracking is activated in the optimization parameters (MODETRACKING=
ON). The default for mode tracking in SIMULIA Tosca Structure
is to take 5 modes into account, but this can be changed with the item
MODENUMBERS. This should not be set too high because
of computational effort.

|
Optimization displacements and convergence plots without (a) and with (b) mode tracking |