The following optimization parameters are available only for frequency response models:
DAMP_STRUCTURAL_MASS = <real> |
Structural mass damping |
DAMP_STRUCTURAL_STIFF = <real> |
Structural stiffness damping |
DAMP_VISCOUS_MASS = <real> |
Viscous mass damping |
DAMP_VISCOUS_STIFF = <real> |
Viscous stiffness damping |
SUM_Q_FACTOR = <real> |
Exponent to emphasize high values Q |
All damping factors are zero, and SUM_Q_FACTOR = 6 by default.