ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEJob module
Optional parameters
- CONTACT
-
This parameter applies only to Abaqus/Standard analyses.
Set CONTACT=YES to print detailed information about the contact constraints generated by the contact pair definition data. Set CONTACT=NO (default) to suppress this printout.
- ECHO
-
Set ECHO=YES to print an echo of the input data. Set ECHO=NO (default) to suppress this printout.
- HISTORY
-
Set HISTORY=YES to print history data. Set HISTORY=NO (default) to suppress this printout.
- MODEL
-
Set MODEL=YES to print model definition data. Set MODEL=NO (default) to suppress this printout.
In Abaqus/Explicit, setting MODEL=YES automatically sets MASS PROPERTY=YES.
- PARSUBSTITUTION
-
Set PARSUBSTITUTION=YES to print the modified version of the original input file that is free of input model parametrization. Set PARSUBSTITUTION=NO (default) to suppress this printout.
- PARVALUES
-
Set PARVALUES=YES to print a modified version of the original input file showing the parameters used for model parametrization and their values. Set PARVALUES=NO (default) to suppress this printout.
- MASS PROPERTY
-
This parameter applies only to Abaqus/Explicit analyses.
Set MASS PROPERTY=YES to print a mass property table, which includes the original mass, initial mass scaling, non-structural mass, center of mass, and rotary inertia of each user-defined element set. Set MASS PROPERTY=NO (default) to suppress this printout.
If MODEL=YES, the mass property table will be printed, even if MASS PROPERTY= NO.
There are no data lines associated with this option.