- PORE FLUID
- 
This parameter applies only to Abaqus/Standard analyses. Include this parameter if the latent heat of the pore fluid in a porous medium is being defined. 

Data lines to define a material's latent heat
- First line
- 
- Latent heat per unit mass. (Units of JM−1.) 
- Solidus temperature. 
- Liquidus temperature. 