ProductsAbaqus/StandardAbaqus/CAE
TypeModel data
LevelPartPart instance
Abaqus/CAEUnsupported; similar functionality (with the
exception of friction) is available by modeling
connectors.
Required parameters
- ELSET
-
Set this parameter equal to the name of the element set containing the ITS-type elements for which properties are being defined.
Data line for ITSUNI elements
- First
(and only) line
-
Tube outside diameter.
-
Distance between the parallel support plates on opposite sides of the tube.
-
X-direction cosine of the axis of the tube.
-
Y-direction cosine of the axis of the tube.
-
Z-direction cosine of the axis of the tube.
-
X-direction cosine of the normal to either one of the
support plates.
-
Y-direction cosine of the normal to either one of the
support plates.
-
Z-direction cosine of the normal to either one of the
support plates.
Data line for ITSCYL elements
- First
(and only) line
-
Tube outside diameter.
-
Diameter of the hole in the support plate.
-
X-direction cosine of the axis of the tube.
-
Y-direction cosine of the axis of the tube.
-
Z-direction cosine of the axis of the tube.