ProductsAbaqus/Standard
 TypeModel data
 
LevelPartPart instanceAssembly
   
Required parameters
 
 - ELSET
 
- Set this parameter equal to the name
of the element set containing the elements that will be activated during the
analysis.
 
 
- NAME
 
- Set this parameter equal to a label
that will be used to refer to this element progressive
activation.
 
 
 

There are no data lines associated with this option.