- ASSEMBLE
-
Include this parameter to write assembled matrices. By default, element matrices are written.
- DAMPING
-
Include this parameter to output the heat capacity matrix.
- ELSET
-
Use this parameter to write matrices for a part of the model. Set this parameter equal to the name of an element set that contains all the elements in the selected part of the model. By default, matrices are generated for all supported elements in the whole model, including internal elements.
- FREQUENCY
-
Set this parameter equal to the output frequency, in increments. The output will always be written at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.
- LOAD
-
Include this parameter to output the flux selected by the LOADTYPE parameter.
- LOADTYPE
-
Use this parameter to select the type of load for output.
Set LOADTYPE=EXTERNAL (default) to output external heat flux.
Set LOADTYPE=NET to output net heat flux.
- STIFFNESS
-
Include this parameter to output the thermal conductivity matrix.