ProductsAbaqus/Explicit TypeModel data LevelModel Required parameters
- ELSET
-
Set this parameter equal to the name of the element set where adaptive mesh refinement is applied.
Optional parameters
- LEVEL
-
Set this parameter equal to the maximum number of levels of refinement. The default value is 1.
- COARSENING
-
Set COARSENING=YES (default) to specify that refinement can be removed once the refinement criteria are no longer met.
Set COARSENING=NO to specify that refinement cannot be removed even when the refinement criteria are no longer met.
- RATIO
-
Set this parameter equal to the ratio of the maximum increase in the number of elements during mesh refinement compared to the original number of elements in the specified element set. The default value is 8.0.
Data lines to define the criteria used in the mesh refinement- First line
Refinement criteria label (see Defining adaptive mesh refinement in the Eulerian domain).
Value of the refinement criteria if applicable.
- Repeat this data line as often as necessary to define multiple criteria for mesh refinement.
|