Context:
For the cantilever beam tutorial, you will simply examine the output requests and accept the default configuration.
In the Model Tree, click mouse button 3 on the Field Output Requests container and select Manager from the menu that appears.
Abaqus/CAE displays the Field Output Requests Manager. This manager displays an alphabetical list of existing output requests along the left side of the dialog box. The names of all the steps in the analysis appear along the top of the dialog box in the order of execution. The table formed by these two lists displays the status of each output request in each step.
Review the default output request that Abaqus/CAE generates for the Static, General step you created and named BeamLoad.
Click the cell in the table labeled Created; that cell becomes highlighted, and the following information related to the cell appears in the legend at the bottom of the manager:
-
The type of analysis procedure carried out in the step in that column.
-
The list of output request variables.
-
The output request status.
On the right side of the Field Output Requests Manager, click Edit to view more detailed information about the output request.
The field output editor appears. In the Output Variables region of the dialog box, a text box lists all the variables that will be output. If you change an output request, you can always return to the default settings by clicking Preselected defaults above the text box.
Click the arrows next to each output variable category to see exactly which variables will be output. The check boxes next to each category title allow you to see at a glance whether all variables in that category will be output. A black check mark on a white background indicates that all variables will be output, while a dark gray check mark on a light gray background indicates that only some variables will be output.
Based on the selections shown at the bottom of the dialog box, data will be generated at every default section point in the model and will be written to the output database after every increment during the analysis.
Click Cancel to close the field output editor, since you do not wish to make any changes to the default choice.
Click Dismiss to close the Field Output Requests Manager.
Note:
What is the difference between the Dismiss and Cancel buttons? Dismiss buttons appear in dialog boxes that contain data that you cannot modify. For example, the Field Output Requests Manager allows you to view output requests, but you must use the field output editor to modify those requests. Clicking the Dismiss button simply closes the Field Output Requests Manager. Conversely, Cancel buttons appear in dialog boxes that allow you to make changes. Clicking Cancel closes the dialog box without saving your changes.
Review the history output requests in a similar manner by clicking mouse button 3 on the History Output Requests container in the Model Tree and then opening the history output editor.