In the optimization task editor, click the
Thickness tab.
Select the Thickness update strategy.
This setting controls the rate at which the
Optimization module
updates the shell thickness of design elements during the optimization using
the method of moving asymptotes. In most cases you should accept the default
setting (Normal). However, if the design responses are
very sensitive and you have problems fulfilling the constraints, you may need a
more conservative rate that requires more optimization iterations. Selecting an
aggressive rate may lead to unstable optimization or prevent the optimization
from converging on a solution.
Enter the Maximum change per design cycle.
This setting controls the limit on the change in shell element
thickness during each design cycle.
|