Double-click the DOE component icon
.
The DOE Component Editor appears.
From the General tab's DOE Technique list, select Optimal Latin Hypercube.
Enter the Number of Points that you want to study. For each defined
factor, the levels are defined by uniformly distributing this number
of points between the specified lower and upper values. These levels
are randomly combined with other factor levels to define each design
point to execute.
You can map this option to a parameter.
Enter the Maximum Time to Optimize (minutes) that the component can
optimize. Once this time limit is reached, the optimization stops.
You can map this option to a parameter.
Click Use a fixed seed Select this option to manually specify the seed in teh corresponding text box. Type the value of the random seed in the corresponding text box. If this option is not selected, Isight determines the seed randomly.
Note:
A fixed seed can also be set and used for the entire model.
If a fixed seed is set for the model and also defined separately in the
DOE component, Isight
uses the one defined in the DOE component. If a fixed seed is set for
the model and this option is not selected, the sequence
of random numbers is based on the model’s random seed (and, thus, is
still reproducible).
For information about setting a fixed seed, see
Setting the Execution Options in the Isight User’s Guide.
Click OK to save your changes and to close the DOE Component Editor.